Tri-Clamp Long Ferrule (14AM7)

Clear
Quantity - +

Description

Long weld tri-clamp ferrules connect sanitary process lines to permanent welded end.

Long weld clamp ferrules allow extra room for welding capabilities when assembling process lines.  Stainless steel design is offered in both 304 and 316L alloy options.  Sizes for this product range from 1/2 inch all the way up to 12 inches.  For joining clamp fittings to welded ends.  Orbital weld is recommended to ensure proper connectivity, tri-clamp connections finish this process line. Recommended products include clamp gaskets and single-pin, heavy duty clamps. Request Material Test Reports (MTRs)

Long Weld Clamp Ferrules Part Numbers & Dimensions

Part Number Cross Reference
Sanitary Fittings Bradford Alfa Laval Waukesha Cherry VNE Top Line Andron®
14AM7 14AM7 L14AM7 L14AM7 EG14AM7 L14AM7 AC14A
Long Weld Clamp Ferrule Dimensions
Size (Tube OD) Part Number Dimensions Wall Thickness Line Drawing
304 316L A B C D
1/2" NA L14AM7-.50-316 1.125 0.370 0.500 0.992 0.065
3/4" NA L14AM7-075-316 1.125 0.620 0.750 0.992 0.065
1" L14AM7-1-304 L14AM7-1-316 1.125 0.870 1.000 1.984 0.065
1-1/2" L14AM7-1.5-304 L14AM7-1.5-316 1.125 1.370 1.500 1.984 0.065
2" L14AM7-2-304 L14AM7-2-316 1.125 1.870 2.000 2.516 0.065
2-1/2" L14AM7-2.5-304 L14AM7-2.5-316 1.125 2.370 2.500 3.047 0.065
3" L14AM7-3-304 L14AM7-3-316 1.125 2.870 3.000 3.579 0.065
4" L14AM7-4-304 L14AM7-4-316 1.125 3.834 4.000 4.682 0.083
6" L14AM7-6-304 L14AM7-6-316 1.500 5.782 6.000 6.562 0.109
8" L14AM7-8-304 L14AM7-8-316 1.500 7.760 8.000 8.602 0.109
10" L14AM7-10-304 L14AM7-10-316 1.500 9.782 10.000 10.570 0.109
12" L14AM7-12-304 L14AM7-12-316 1.500 11.760 12.000 12.570 0.120

Watch How to Measure Tri-Clamp Fittings

Tri-Clamp Fittings and Gasket Sizing Guide

Sanitary Fitting Dimensions
Sanitary Size OD of Flange End ID of Tube OD of Tube
1/2″ 0.992 0.370 0.500
3/4″ 0.992 0.620 0.750
1″ 1.984 0.870 1.000
1 1/2″ 1.984 1.370 1.500
2″ 2.516 1.870 2.000
2 1/2″ 3.047 2.370 2.500
3″ 3.579 2.870 3.000
4″ 4.682 3.834 4.000
6″ 6.562 5.782 6.000
8″ 8.602 7.782 8.000
10″ 10.570 9.782 10.000
12″ 12.570 11.760 12.000

Reviews

Questions & Answers 2

Questions and answers of the customers

  1. Q Is this product ASME certified?
    A I'm sorry, but most of the products available on Sanitary Fittings are not ASME certified. ASME is usually required within the bio-pharmaceutical industry and is not typical for most installations. Our heavy duty tank weld ferrule is the only product that we sell to meet that certification at the moment. Please check back often and our product line continues to expand.
  2. Q What is the OD of the flange? please
    A Hello, great question! This comes up very often with tri-clamp / tri-clover fittings. The OD diameter of the flange varies with the sanitary fitting size. In all cases, the outside diameter of the flange will be GREATER than the sanitary fitting diameter. This is a common mistake for people new to purchasing sanitary fittings.   Please refer to our Sanitary Fittings Dimensions guide to answer all your sizing questions related to tri-clamp fittings.

Send me a notification for each new answer.