SKUs available on this product page

16AI-14I-6-316, 16AI-14I-1-316, 16AI-14I-1.5-316, 16AI-14I-2-316, 16AI-14I-2.5-316, 16AI-14I-3-316, 16AI-14I-4-316, 16AI-14I-4-304, 16AI-14I-3-304, 16AI-14I-2.5-304, 16AI-14I-2-304, 16AI-14I-1.5-304, 16AI-14I-1-304, 16AI-14I-6-304,

Male I-Line End Cap (16AI-14I)

  • Sanitary Male I-Line End Cap (16AI-14I)
  • Available in 304 Stainless Steel
  • 3A Certified for sanitary-grade line process equipment
Quantity - +

Cap existing process line with male I-line end cap

I-Line fittings provide a rigid, leak-resistant seal, joining two separate tube fitting components.  Available in both 304 Stainless Steel alloy, providing both strength and durability.  This product is 3A certified for use inline process applications where sanitary conditions are a requirement.

Male I-Line End Cap Dimensions

Part Number Size (inches) A B C
16AI-14I-1 1" 0.505" Request Drawing
16AI-14I-1.5 1 1/2" 0.505" Request Drawing
16AI-14I-2 2" 0.505" 2.643" 2.245"
16AI-14I-2.5 2 1/2" 0.692" 3.310" 2.743"
16AI-14I-3 3" 0.692" 3.873"
16AI-14I-4 4" 0.755" PDF
16AI-14I-6 6" 0.755" 7.498" 6.905"

Additional information

Line Drawings

SKUDescriptionLine Drawing
16AI-14I-1-304

1″ Male I-Line Solid End Cap 304

Request Line Drawing
16AI-14I-1-316

1″ Male I-Line Solid End Cap 316

Request Line Drawing
16AI-14I-1.5-304

1 1/2″ Male I-Line Solid End Cap 304

Request Line Drawing
16AI-14I-1.5-316

1 1/2″ Male I-Line Solid End Cap 316

Request Line Drawing
16AI-14I-2-304

2″ Male I-Line Solid End Cap 304

PDF
16AI-14I-2-316

2″ Male I-Line Solid End Cap 316

PDF
16AI-14I-2.5-304

2 1/2″ Male I-Line Solid End Cap 304

PDF
16AI-14I-2.5-316

2 1/2″ Male I-Line Solid End Cap 316

PDF
16AI-14I-3-304

3″ Male I-Line Solid End Cap 304

PDF
16AI-14I-3-316

3″ Male I-Line Solid End Cap 316

PDF
16AI-14I-4-304

4″ Male I-Line Solid End Cap 304

PDF
16AI-14I-4-316

4″ Male I-Line Solid End Cap 316

PDF
16AI-14I-6-304

6″ Male I-Line Solid End Cap 304

PDF
16AI-14I-6-316

6″ Male I-Line Solid End Cap 316

PDF

    I have a header that is capped with 8" I-Line fittings. The water pressure is 60 psi in this tube. I am trying to learn why they would have designed this with the I line and not just a standard Tri-Clamp fitting. Any information would be appreciated.
  1. Q I have a header that is capped with 8" I-Line fittings. The water pressure is 60 psi in this tube...... Read more
    A A lot of dairy applications utilize I-Line fittings. There is no advantage either way between I-Line vs Tri-Clamp fittings other than the tri-clamp fittings are more readably accessible. Since the tube outside diameters is the same, one option you can take is to remove the current I-Line fitting and weld in place a new tri-clamp ferrule.