SKUs available on this product page

2E-75-NA, 1KS-75-NA, 2E-10-NA, 1KS-10-NA, 2E-15-NA, 1KS-15-NA, 2E-20-NA, 1KS-20-NA, 2E-30-NA, 1KS-30-NA, 1KS-40-NA,

Diaphragm Valve Bayonet Replacement

  • Weir-Type Spare Diaphragm Valve Bayonet Replacement
  • Available in EPDM and MPTFE/EPDM Materials
  • Sizes ranging from 3/4″ – 4″
Quantity - +

Replacement Parts for Diaphragm Valve Bayonet

From time to time, diaphragm valves will need the bayonet to be replaced. TOP-FLO® bayonet replacement parts are specifically designed to fit in the diaphragm valves of not only TOP-FLO® valves but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.

Threaded connection assembled by screwing the diaphragm stud into the compressor thread. Bayonet model is assembled by rotating the diaphragm insert into the compressor and rotating 90-Degrees.

BioPro Diaphragms are interchangeable for the following brands, materials and sizes:

ITT ½” – 6” FOR EPDM DIAPHRAGM MATERIAL
ITT NONE FOR TEFLON DIAPHRAGM MATERIAL
SAUNDERS 1” – 6” FOR EPDM DIAPHRAGM MATERIAL
SAUNDERS ½” – 6” FOR TEFLON DIAPHRAGM MATERIAL
BURKERT 1” – 6” FOR EPDM DIAPHRAGM MATERIAL
BURKERT ¼” – 6” FOR TEFLON DIAPHRAGM MATERIAL
GEMU Not compatible
SED Not compatible

 

Additional information

Line Drawings

SKUDescriptionLine Drawing
1KS-10-NA

1″ MPTFE/EPDM Diaphragm Valve Replacement Bayonet, Bayonet Connection, FDA/USP CLASS VI (DN25)

Request Line Drawing
1KS-15-NA

1 1/2″ MPTFE/EPDM Diaphragm Valve Replacement Bayonet, Bayonet Connection, FDA/USP CLASS VI (DN40)

Request Line Drawing
1KS-20-NA

2″ MPTFE/EPDM Diaphragm Valve Replacement Bayonet, Bayonet Connection, FDA/USP CLASS VI (DN50)

Request Line Drawing
1KS-30-NA

2 1/2″ MPTFE/EPDM Diaphragm Valve Replacement Bayonet, Bayonet Connection, FDA/USP CLASS VI (DN80)

Request Line Drawing
1KS-40-NA

4″ MPTFE/EPDM Diaphragm Valve Replacement Bayonet, Bayonet Connection, FDA/USP CLASS VI (DN100)

Request Line Drawing
1KS-75-NA

3/4″ MPTFE/EPDM Diaphragm Valve Replacement Bayonet, Bayonet Connection, FDA/USP CLASS VI (DN20)

Request Line Drawing
2E-10-NA

1″ EPDM Diaphragm Valve Replacement Bayonet, Peroxide Cured, Threaded Connection, FDA/USP CLASS VI (DN25)

Request Line Drawing
2E-15-NA

1 1/2″ EPDM Diaphragm Valve Replacement Bayonet, Peroxide Cured, Threaded Connection, FDA/USP CLASS VI (DN40)

Request Line Drawing
2E-20-NA

2″ EPDM Diaphragm Valve Replacement Bayonet, Peroxide Cured, Threaded Connection, FDA/USP CLASS VI (DN50)

Request Line Drawing
2E-30-NA

2 1/2″ EPDM Diaphragm Valve Replacement Bayonet, Peroxide Cured, Threaded Connection, FDA/USP CLASS VI (DN80)

Request Line Drawing
2E-75-NA

3/4″ EPDM Diaphragm Valve Replacement Bayonet, Peroxide Cured, Threaded Connection, FDA/USP CLASS VI (DN20)

Request Line Drawing

    I'm looking 2" Saunders bayonet diaphragms, 2 piece Teflon and EPDM, DN-50. When I select Additional Information, it says "bayonet" and "screwed". What is your part # for the 2" bayonet diaphragm I need? Thanks.
  1. Q I'm looking 2" Saunders bayonet diaphragms, 2 piece Teflon and EPDM, DN-50. When I select Additio...... Read more
    A

    The part number for this valve replacement part is 1KS-20-NA.  I will send you a quote for this item now.

  2. What is the difference between the two connection types beyond just material?
  3. Q What is the difference between the two connection types beyond just material?
    A

    The EPDM is threaded and the stud is molded into the diaphragm.  This option is both cheaper and easier to produce which is why it is not the preferred style.



    The PTFE has the bayonet because years ago they had threaded inserts and the people in the field would overtighten them and pull the stud out of the PTFE and break them. They came up with the bayonet design to stop the overtightening but for some reason the EPDM model was never updated so we now offer both connection styles.